Fire Door Head / Jamb Gap Solutions — Up To 90 Minutes
Product Features
- UL Certified Solution for 60 and 90 Minute Fire Doors with Excessive Clearance Between Door and Frame Over 1/8", up to 3/8".
- UL Certified Solution for 20 and 45 Minute Fire Doors with Excessive Clearance Between Door and Frame Over 1/8", up to 9/16".
- Restricts the Passage of Smoke
- Non-Handed
- Available in 36", 48", 84" and 96" Lengths
- Designed for Use Where Door Frame Stop is Less Than 1-3/8" Wide
- An NGP Strike Shim (9275 or 9225) may also be Required for Proper Latchbolt Engagement
- Certified for use in US and Canada
- Patented: US Patent 9,273,510 B2
- Charcoal
Standards

POSITIVE PRESSURE – CERTIFIED by UL to ANSI/UL10C, complies with IBC, NFPA 80 and NFPA 252 for application to Hollow Metal and Wood fire doors rated up to 90 minute with excessive door and frame clearances, measuring up to 3/8"; and rated up to 45 minutes with excessive clearances up to 9/16".

CERTIFIED by UL to ANSI/UL10B, complies with NFPA 80 and NFPA 252 for application to Hollow Metal and Wood fire doors rated up to 90 minute with excessive door and frame clearances, measuring up to 3/8"; and rated up to 45 minutes with excessive clearances up to 9/16".